Manage a multi-datacenter crush map with the command line

loic

A new datacenter is added to the crush map of a Ceph cluster:

# ceph osd crush add-bucket fsf datacenter added bucket fsf type datacenter to crush map

ceph osd crush move fsf root=default

moved item id -13 name 'fsf' to location {root=default} in crush map

ceph osd tree

id weight type name up/down reweight

-13 0 datacenter fsf -5 7.28 datacenter ovh -2 1.82 host bm0014 0 1.82 osd.0 up 1 ...

The datacenter bucket type already exists by default in the default crush map that is provided when the cluster is created. The fsf bucket is moved ( with crush move ) to the root of the crush map.

A new rule is created to take objects in the fsf datacenter and ensure no host holds more than one copy:

# ceph osd crush rule create-simple fsf-rule fsf host

ceph osd crush rule dump

... { "rule_id": 6, "rule_name": "fsf", "ruleset": 6, "type": 1, "min_size": 1, "max_size": 10, "steps": [ { "op": "take", "item": -13}, { "op": "chooseleaf_firstn", "num": 0, "type": "host"}, { "op": "emit"}]}]

A new pool is created and associated with the newly created rule ( id 6 ):

# ceph osd pool create fsf 128 pool 'fsf' created

ceph osd pool set fsf crush_ruleset 6

set pool 7 crush_ruleset to 6

The OSDs are automatically added to the fsf bucket by adding the following to /etc/ceph/ceph.conf:

osd_crush_update_on_start = 1 osd_crush_location = datacenter=fsf

It is interpreted by the ceph-osd upstart script that is triggered when a new OSD is created or when the machine boots.

# ceph-deploy osd create bm0101.the.re:/dev/sdb:/dev/sdc ...

ceph osd tree

... -13 3.64 datacenter fsf -14 3.64 host bm0101 8 3.64 osd.8 up 1